Speak to a world-class expert now.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
PrimeTrack® Instant Conferencing
PrimeTrack® Project Management System (patent pending)
Lead Consultant
KPP is a Mechanical Engineer, Thermal and Fluid Systems Engineer, Engineering Consultant with world-class expertise in thermal systems engineering design, component sizing, integration and analysis, analysis of heat transfer, fluid flow/piping systems
Contact us now to speak to this world-class, top-level expert.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
Or, contact this expert directly.
For additional or different expertise, browse other top-level expert resumes in Expert Testimony, Failure Analysis, Manufacturing Optimization, KKAI's Center for Rapid Response Engineering® Solutions and a host of other Engineering and Scientific Consulting services.
Learn how KKAI assembles expert teams of any size or skill set combination to meet our clients' needs on a rapid-response basis - no matter how complex the challenge.
Or, peruse our 325 case studies or 475 other expert resumes.
The STS Orbiter Radiator System includes a Flow Control Assembly which maintains control of the temperature of the liquid Refrigerant 21 flowing from the radiator system to the Freon Coolant Loop. The Flow Control Assembly nominally controls the Freon Coolant Loop inlet temperature to 38°F +/- 2°F. The Flow Control Assembly also contains an emergency radiator bypass mode which will stop radiator system fluid flow if the radiator exit temperature becomes less than 33°F +/- 0.5°F. This prevents freezing temperatures from reaching the cabin heat exchanger which contains water.
Well into the Shuttle Orbiter design phase, two challenging requirements were added to the Flow Control Assembly. The first challenge consisted of an added requirement for a rapid radiator inlet temperature transient that must be accommodated. An oil cooler heat exchanger upstream of the radiator would cause the radiator inlet temperature to decrease at a rate of 2.5°F/second when oil flow in the heat exchanger was activated. This rapid change could cause the radiator control temperature (at 38°F) to dive below the emergency activation temperature 33°F in a few seconds. A modification of the control laws was required to provide a rapid control response to the inlet temperature changes. The original linear control (valve rate of movement proportional to the sensed temperature error) was modified to add a nonlinear control component (valve rate of movement was proportional to the sensed temperature error plus the rate of change of the temperature error). The control gains were also tailored to achieve the desired rapid control. Testing demonstrated that the control performance exceeded the customer needs following the change.
The second challenge resulted from the fact that the radiator system pressure drop would vary with position of the radiator bypass valve causing flow variations in the entire Freon Coolant Loop. This was found to cause problems with the pump module and other components in the Freon Coolant Loop. The customer added the requirement to maintain a near-constant radiator pressure drop regardless of the temperature control valve position and resulting radiator flow. A two-fold solution was found for this problem. First the radiator system was balanced by sizing the bypass line to provide the same pressure drop at full bypass as the pressure drop in the radiator at full radiator flow. Second, a requirement was placed on purchased temperature control valve to tailor the pressure drop as a function of valve position, adding a pressure drop profile for the intermediate valve positions. These design additions provided the flow/pressure drop characteristics needed by the customer.
This KKAI Associate was the Principle Engineer, performing all analyses and directing all testing on this effort. An electrical engineer modified the electronic controller to achieve the required control laws.
Read other articles by this KKAI Associate:
Design of the International Space Station Radiators to Tolerate Fluid Freezing
Evaluation of the Thermal Performance of a Potential New Product Line for Electronic Cooling Devices
| Mechanical Engineer, Thermal and Fluid Systems Engineer, Engineering Consultant, thermal systems engineering design, component sizing, integration and analysis, analysis of heat transfer, fluid flow/piping systems | |
| Resume of NLG | research and development scientist, jet propulsion engineer, engineering failure analysis, accident reconstruction consultant, specialist, forensic analysis investigation expert witness testimony, engineering consulting services |
| Resume of KPH | electrical design engineer, nuclear engineer, engineering manager, program manager, project engineer, marketing and financial consultant, accident investigation, accident reconstruction, specialist, forensic analysis investigation expert witness testimony, engineering consulting services |
| Resume of SPC | mechanical engineer, control systems consultant, engineering consultant, engineering failure analysis, specialist, forensic analysis investigation expert witness testimony, engineering consulting services |
| Resume of RAC | mechanical engineer, heat transfer fluid mechanics consultant, engineering failure analysis, accident reconstruction specialist, forensic analysis expert, expert witness testimony, engineering consulting services |
To search for specific expertise, enter your search query (type of
expertise you are seeking) in the box below, choose to search the entire
Rapid-Response site or just resumes and brochures, then click the search button.
Please note that the list of resumes available online is a select subset of our
vast database. If your search of our site does not reveal the expertise you are
seeking, please call us toll-free (in the U.S.) at 1-800-367-5524 or
contact us for more information and we will gladly assist you in
locating the specific expertise you require.
Have an urgent litigation support or engineering and scientific consulting need? Contact KKAI now for world-class, expert rapid response.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
BACK TO THE TOP OF THIS PAGE
Kevin Kennedy & Associates, Inc.
Rapid Response Engineering® Solutions
3905 Vincennes Road, Suite 320
Indianapolis, Indiana 46268
(317) 536-7000 voice
(317) 536-7220 fax