Speak to a world-class expert now.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
PrimeTrack® Instant Conferencing
PrimeTrack® Project Management System (patent pending)
Consultant
QSG is a Chief Engineering Scientist, Consulting Engineer, Research Scientist, Noise and Vibration Control Specialist, Acoustics, Structural And Machinery Dynamics, Noise And Vibration Control, And Stress Analysis Consultant with world-class expertise in structureborne sound, structural and machinery dynamics, noise and vibration control, and stress analysis.
Speak to this experienced, world-class expert now.
For additional or different expertise, browse other top-level expert resumes in Expert Testimony, Failure Analysis, Manufacturing Optimization, KKAI's Center for Rapid Response Engineering® Solutions and a host of other Engineering and Scientific Consulting services.
Learn how KKAI assembles expert teams of any size or skill set combination to meet our clients' needs on a rapid-response basis - no matter how complex the challenge.
Or, peruse our 400 case studies or 500 other expert resumes.
The MIT/Harvard Center for Magnetic Resonance plans called for the installation of a 900 MHz Nuclear Magnetic Resonance (NMR) device. Unfortunately, a very large generator next door produced a narrow-band vibration peak at 28 Hz that exceeded the NMR's vibration criterion.
This consultant surveyed the floor vibrations and determined ways to reduce the vibrations to acceptable levels, considering that potential solutions had to accommodate the NMR's own internal vibration isolation system.
This consultant determined that the generator-induced vibrations could be reduced to acceptable levels using high-performance commercial air spring isolators (natural frequencies: 1.5 Hz vertical, 1.2 Hz horizontal). We recommended an 80,000 pound inertia block to dynamically separate the primary isolation system from the NMR isolators, thereby minimizing adverse interactions between the two isolation systems.
The above photo shows the underside of the block with the air spring isolators; the photo below shows the top surface of the block where the NMR is now located. At the generator's operating frequency, the system attenuates the floor vibrations by 45 db, allowing the researchers to use the NMR even while the generator is in service.
Read other articles by this KKAI Associate:
Brain And Cognitive Sciences Project Rail vibration, Transfer mobility testing
New York Structural Biology Center Vibration Measurements and Analysis
National Institute Of Standards And Technology
Beth Israel Deaconess Medical Center Vibration survey and analysis
National Neuroscience Research Center Vibration Analysis
| Chief Engineering Scientist, Consulting Engineer, Research Scientist, Noise and Vibration Control Specialist, Acoustics, Structural And Machinery Dynamics, Noise And Vibration Control, And Stress Analysis Consultant, structureborne sound, structural and machinery dynamics, noise and vibration control, and stress analysis. | |
| Resume of EZU | engineering mechanics, stress, dynamics expert consultant |
| Resume of CWR | fracture mechanics, crack propagation expert consultant |
| Resume of SPC | mechanical, control systems expert consultant |
| Resume of GLN | acoustics, vibration, vehicle dynamics, expert consultant |
| Resume of RBE | gearbox design, structural dynamics, expert consultant |
To search for specific expertise, enter your search query (type of
expertise you are seeking) in the box below, choose to search the entire
Rapid-Response site or just resumes and brochures, then click the search button.
Please note that the list of resumes available online is a select subset of our
vast database. If your search of our site does not reveal the expertise you are
seeking, please call us toll-free (in the U.S.) at 1-800-367-5524 or
contact us for more information and we will gladly assist you in
locating the specific expertise you require.
Have an urgent litigation support or engineering and scientific consulting need? Contact KKAI now for world-class, expert rapid response.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
BACK TO THE TOP OF THIS PAGE
Kevin Kennedy & Associates, Inc.
Rapid Response Engineering® Solutions
3905 Vincennes Road, Suite 320
Indianapolis, Indiana 46268
(317) 536-7000 voice
(317) 536-7220 fax