Speak to a world-class expert now.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
PrimeTrack® Instant Conferencing
PrimeTrack® Project Management System (patent pending)
Consultant
DCY is a Cleanroom Design / Build Expert, HVAC Engineering Consultant, Electronic Facilities Engineer, Energy Conservation Consultant, Sustainability Specialist with world-class expertise in HVAC product design, sales, service, installation, facility design / build, manufacturing, operations, teaching, consultation, project design management, construction supervision and certification of industrial facilities serving electronic, semiconductor, bio-pharmaceutical, optics, and allied "high tech" firms.
Speak to this experienced, world-class expert now.
For additional or different expertise, browse other top-level expert resumes in Expert Testimony, Failure Analysis, Manufacturing Optimization, KKAI's Center for Rapid Response Engineering® Solutions and a host of other Engineering and Scientific Consulting services.
Learn how KKAI assembles expert teams of any size or skill set combination to meet our clients' needs on a rapid-response basis - no matter how complex the challenge.
Or, peruse our 400 case studies or 500 other expert resumes.
A small area of a manufacturing plant had been upgraded to a laboratory environment and was equipped with a clean bench within which was to be performed assembly of sensitive prototype electronic components. The clean bench was a downflow design with a HEPA filter installed above the work surface. Acceptance testing showed the filter to be leak-free and the technicians involved in product assembly were observed by this consultant to be working in an appropriate manner. However the client indicated that the quality of products assembled on this bench was erratic and particulate contamination was suspected. At the consultants' suggestion, a particle counter was installed within the bench on the work surface and particle counts were observed over time. Within a short time it was noted that periods of low particle counts were interspersed with periods of exceptional high counts.
This consultants' inspection of the laboratory space showed that it had been meticulously cleaned and all surfaces were either of new, non-shedding materials, or had been coated with a non-shedding epoxy finish. A pattern of high vs low counts was observed and ultimately related to the cycling of the airconditioning system serving the laboratory. Further inspection showed that while new, clean filters, had been installed in the airconditioning system during the upgrade process, the filters were direct replacements for the low efficiency furnace filters commonly found in airconditioning equipment of that type. Whenever the airconditioner cycled "ON" to maintain room temperature, particle laden air delivered from ceiling mounted air diffusers would blow into the clean bench work area and mix with the highly filtered air flowing from the HEPA filtration system of the clean work bench with resulting high particle counts. The recommended solution, of replacing the diffusers with ceiling mounted HEPA filter units, cleaned up the conditioned air being delivered to the lab space. While there was an increased pressure drop caused by the new HEPA filters, it was not enough to require a larger, replacement, fan motor. In this case the high pressure drop of the HEPA filters was overcome by adjusting the airconditioning fan speed. Particle counts were noted to be consistently within specification from that point forward and product quality met expectations.
Read other articles by this KKAI Associate:
Cleanroom Training and Conceptual Design
Troubleshooting Humidity Problems in a Manufacturing Environment
| Cleanroom Design / Build Expert, HVAC Engineering Consultant, Electronic Facilities Engineer, Energy Conservation Consultant, Sustainability Specialist, HVAC product design, sales, service, installation, facility design / build, manufacturing, operations, teaching, consultation, project design management, construction supervision and certification of industrial facilities serving electronic, semiconductor, bio-pharmaceutical, optics, and allied "high tech" firms. | |
| Resume of NLG | research, development, jet propulsion expert consultant |
| Resume of SCM | cleanroom, environmental assessment expert consultant |
| Resume of PUL | environmental, research, technical expert consultant |
| Resume of XVS | construction, fema disaster, inspection expert consultant |
| Resume of KPP | mechanical, thermal, fluid systems expert consultant |
To search for specific expertise, enter your search query (type of
expertise you are seeking) in the box below, choose to search the entire
Rapid-Response site or just resumes and brochures, then click the search button.
Please note that the list of resumes available online is a select subset of our
vast database. If your search of our site does not reveal the expertise you are
seeking, please call us toll-free (in the U.S.) at 1-800-367-5524 or
contact us for more information and we will gladly assist you in
locating the specific expertise you require.
Have an urgent litigation support or engineering and scientific consulting need? Contact KKAI now for world-class, expert rapid response.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
BACK TO THE TOP OF THIS PAGE
Kevin Kennedy & Associates, Inc.
Rapid Response Engineering® Solutions
3905 Vincennes Road, Suite 320
Indianapolis, Indiana 46268
(317) 536-7000 voice
(317) 536-7220 fax