Speak to a world-class expert now.
1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com
PrimeTrack® Instant Conferencing
PrimeTrack® Project Management System (patent pending)


LITIGATION SUPPORT SERVICES


CENTER FOR RAPID RESPONSE ENGINEERING® SOLUTIONS

ENGINEERING AND SCIENTIFIC CONSULTING SERVICES

Troubleshooting Humidity Problems in a Manufacturing Environment

Consultant
DCY is a Cleanroom Design / Build Expert, HVAC Engineering Consultant, Electronic Facilities Engineer, Energy Conservation Consultant, Sustainability Specialist with world-class expertise in HVAC product design, sales, service, installation, facility design / build, manufacturing, operations, teaching, consultation, project design management, construction supervision and certification of industrial facilities serving electronic, semiconductor, bio-pharmaceutical, optics, and allied "high tech" firms.

Speak to this experienced, world-class expert now.

For additional or different expertise, browse other top-level expert resumes in Expert Testimony, Failure Analysis, Manufacturing Optimization, KKAI's Center for Rapid Response Engineering® Solutions and a host of other Engineering and Scientific Consulting services.

Learn how KKAI assembles expert teams of any size or skill set combination to meet our clients' needs on a rapid-response basis - no matter how complex the challenge.

Or, peruse our 400 case studies or 500 other expert resumes.


Search Entire Rapid-Response Site
Search Resumes Only
Case Studies

A Michigan medical device manufacturer was performing certain processes in a clean facility designed to maintain a temperature of 70+/-2ºF and 40+/-2% RH. The owner observed, over a period of time, the mechanical system failure to maintain the desired humidity level. This consultant was called in to examine the mechanical system to determine why there were extended periods of "out of spec" performance of this system. It was observed that a "standard" packaged airconditioning unit, similar to that typically used in ordinary comfort cooling applications, had been installed along with a humidifier and electric reheat package. The humidification equipment was observed to be functioning adequately in response to the system controls. The major problem with humidity control was observed during periods of high ambient humidity and temperature. The use of a "standard" airconditioning unit was suggested by the consultant as a possible cause of the problem. Further review of the design documents showed that the installed unit did not have the required controls to maintain the desired level of dehumidication. The unit would cool adequately however the humidity controller would continually call for operation of the equipment to remove moisture from the airstream, even after room temperature had been satisfied. The evaporator coil of the unit would develop a coating of ice that reduced airflow, created an abnormally low evaporator refrigerant pressure and would ultimately cause the equipment to shut down on a safety control before satisfying the dehumidification requirement.

The solution to the problem was to reconfigure the refrigerant piping of the airconditoning unit. An evaporator pressure regulator was added to insure that suction pressure would not drop to a point where freezing would occur. This regulator was set to maintain a leaving dew point consistent with the 40% RH requirement. The result was that the airconditioning unit could now run for an extended period, removing moisture from the airstream, with no ice formation and no premature shutdown. The alternative solution involved replacing the airconditioner with a "process" unit more suited to this dehumidification application, but such a solution would have resulted in unacceptable downtime as well as being more costly to implement.

Read other articles by this KKAI Associate:

Cleanroom Training and Conceptual Design

Contamination Control in an Upgraded Laboratory

Cleanroom Design / Build Expert, HVAC Engineering Consultant, Electronic Facilities Engineer, Energy Conservation Consultant, Sustainability Specialist, HVAC product design, sales, service, installation, facility design / build, manufacturing, operations, teaching, consultation, project design management, construction supervision and certification of industrial facilities serving electronic, semiconductor, bio-pharmaceutical, optics, and allied "high tech" firms.
Resume of NLG research, development, jet propulsion expert consultant
Resume of SCM cleanroom, environmental assessment expert consultant
Resume of PUL environmental, research, technical expert consultant
Resume of XVS construction, fema disaster, inspection expert consultant
Resume of KPP mechanical, thermal, fluid systems expert consultant

To search for specific expertise, enter your search query (type of expertise you are seeking) in the box below, choose to search the entire Rapid-Response site or just resumes and brochures, then click the search button. Please note that the list of resumes available online is a select subset of our vast database. If your search of our site does not reveal the expertise you are seeking, please call us toll-free (in the U.S.) at 1-800-367-5524 or contact us for more information and we will gladly assist you in locating the specific expertise you require.


Search Entire Rapid-Response Site
Search Resumes Only
Case Studies


Have an urgent litigation support or engineering and scientific consulting need? Contact KKAI now for world-class, expert rapid response.

1-800-FOR-KKAI (1-800-367-5524)
info@kkai.com

BACK TO THE TOP OF THIS PAGE
Kevin Kennedy & Associates, Inc.
Rapid Response Engineering® Solutions
3905 Vincennes Road, Suite 320
Indianapolis, Indiana 46268
(317) 536-7000 voice
(317) 536-7220 fax

SEARCH our site

Search Entire Site
Resumes Only
Case Studies

Our innovative, proprietary and patent-pending PrimeTrack® Rapid Response capabilities can help you quickly find the experts you are looking for.

Search here to examine any of the more than 500 resumes for KKAI lead consultants and associated experts from our global organization.

Simply enter the type of expertise you seek, and then choose to search the entire Rapid Response site, to just read resumes only, or to read any of KKAI's more than 400 case studies. A rapidly growing organization, KKAI adds more than 20 expert resumes and 40 expert case studies to its Web site each month, so check back often.


CALL US TODAY
Call KKAI with an urgent need. Experts are paged instantaneously and can be made available in a virtual conference room. To experience this unique capability, please call us at 1-800-FOR-KKAI (1-800-367-5524) from the United States or 317-536-7000 if calling internationally.